When creating image, you can use the Image Setup Utility (imgsetup.exe). The Image Setup Utility helps you use the hard drive imaging technology to deploy the client. Run this tool after OSCE client is installed on the image and before the copies of the image is made. It will ask the OfficeScan client to regenerate a GUID once the image is loaded on new machines.
In OfficeScan 8.0, the GUID is checked upon registration. Duplicate GUIDs are listed in the \pccsrv\chkguid.log file. Client listed in this file has a duplicate GUID. To force a client to generate a new one, you need to run Verify Connection from the management console. A scheduled Verify Connection may be set up to run once a day. Result of this Verify connection task can be found in \pccsrv\verconn.log file.
This utility is however not supported on Vista